CONNECTION DIAGRAMS

23

RANGER 8 LPG

CONNECTION OF RANGER 8 TO LN-7 & K240 CONTACTOR KIT

WARNING: Turn the power off when making connections.

N.A. Use power source polarity switch to set for desired electrode

polarity. Position the output selector switch on the power
source to the CV position.

N.B. 3 conductor #16 power cord physically suitable for the instal-

lation and plug rated at 115 volts 15 amperes AC.

N.C. Plug into 115 volt AC receptacle on welder control panel or

other 115 volt AC supply rated at a minimum of 500 volt-
amperes.

N.D. Leads #21 and GND. do not appear on LN-7

s with codes

below 7026.

N.E. Welding cables must be of proper capacity for the current

and duty cycle of immediate and future applications.

N.F. If LN-7 is equipped with a meter kit, extend lead #21 using

#14 or larger insulated wire physically suitable for the installa-
tion. An S16586-

length

remote voltage sensing work lead

G N D .

3 2

2

4

3 1

T O L N - 7

32

2

4

31

P O W E R
S O U R C E

A U T O .
E Q U I P .

W O R K E L E C T R O D E

P O W E R
S O U R C E

7 5

7 6

7 7

K 2 4 0 C O N T A C T O R K I T

2 1

1 1 5 V ( 5 0 / 6 0 H Z . )
( N O T E : 6 0 0 A M P C A P A C I T Y )

E L E C T R O D E C A B L E T O L N - 7

T O W O R K

C O N T R O L C A B L E

C O N N E C T T H E C O N T R O L C A B L E
G R O U N D L E A D T O T H E F R A M E

T H E T E R M I N A L S T R I P O R T O
A N U N P A I N T E D F R A M E S C R E W .

N . D .

N . J .

N . F . & N . G .

N . B .

N . C .

T E R M I N A L M A R K E D N E A R

C O N N E C T I O N O F L N - 7 & K 2 4 0 C O N T A C T O R K I T W I T H 1 1 5 V O L T A C A U X I L I A R Y P O W E R A N D C V O U T P U T

W E L D E R S T A N D A R D O U T P U T T E R M I N A L S

S17742
10-2-92

may be ordered for this purpose. Connect it directly to the
work piece independent of the welding work cable. For conve-
nience, this extended #21 lead should be taped to the welding
work lead.

N.G. Tape up bolted connection where lead #21 is extended.

N.H. Idler switch on power source must be in high idle position.

N.J. If an optional remote output control is used, connect it to this

terminal strip or 6 pin Amphenol receptacle. NOTE: Terminal
strip or 6 pin Amphenol receptacle not available on all power
sources.

CAUTION: Any speed up of the engine RPM by changing the gov-

ernor setting or over-riding the throttle linkage will cause an
increase in the AC auxiliary voltage. If this voltage goes
above 140 volts, the LN-7 control circuit will be damaged. The
engine governor setting is pre-set at the factory - do not
adjust above RPM specifications listed in engine welder oper-
ating manual.

M 1 7 4 8 6

ELECTRODE CABLE

LN-25

WIRE FEEDER

REMOTE CONTROL

TO WORK

ELECTRODE

N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION.

TO WORK

WORK CLIP LEAD

TO WORK

6 PIN
AMPHENOL

N.C. IF OPTIONAL REMOTE OUTPUT CONTROL IS USED, PLACE OUTPUT CONTROL SWITCH
IN "OUTPUT CONTROL REMOTE" POSITION.

RANGER 8 / LN-25 ACROSS THE ARC CONNECTION DIAGRAM

C R M 2 1 8 8 3

OPTIONAL K444-1

N.B. USE POLARITY SWITCH TO SET FOR DESIRED ELECTRODE POLARITY. POSITION THE OUTPUT SELECTOR
SWITCH TO THE WIRE FEED (CV) POSITION.

WARNING

Do not operate with panels open.
Disconnect NEGATIVE (-) BATTERY LEAD
before servicing.

Do not touch electrically live parts.

Keep guards in place.
Keep away from moving parts.
Only qualified personnel should install,use
or service this equipment.