TROUBLESHOOTING

SP 170-I

Observe Safety Guidelines detailed in the beginning of this manual.

PROBLEMS
(SYMPTOMS)

Major physical or electrical damage
is evident.

No wire feed, weld output or gas
flow when gun trigger is pulled. Fan
does NOT operate.

No wire feed, weld output or gas
flow when gun trigger is pulled Fan
operates normally.

POSSIBLE AREAS OF
MISADJUSTMENT(S)

None
Contact your local Authorized Field
Service Facility.

1. Make sure correct voltage is

applied to the machine. See
Installation section,

Electrical

Connections

.

2. Make certain that power switch

is in the ON position.

3. Make sure circuit breaker inside

wire drive compartment is reset.

1. The thermostat may be tripped

due to overheating. Let machine
cool. Weld at lower duty cycle.

2. Check for obstructions in air

flow.

3. Check Gun Trigger connections.

See Installation section.

4. Gun trigger may be faulty.

RECOMMENDED
COURSE OF ACTION

Contact your local Lincoln
Authorized Field Service Facility.

OUTPUT PROBLEMS

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
LOCAL AUTHORIZED LINCOLN ELECTRIC FIELD SERVICE FACILITY for assistance before you proceed.