Installation – Lincoln Electric IM889 VANTAGE 400 (CE) User Manual

Page 12

Advertising
background image

A-2

INSTALLATION

VANTAGE

®

400 (CE)

A-2

(5)

Center-Tapped to ground.

MODEL NUMBERS

K2502-1, -3 (UK)

K2502-2, -4 (EUROPE)

MACHINE SPECIFICATIONS

Receptacles

Residual Current Device (RCD)

Circuit Breakers (Thermal/Magnetic)

Other Circuit Breakers

400V (3 Ph) x 1
230V (1 Ph) x 1

115V x 1

(5)

14 Pin Connector

6 Pin Connector

4-pole, 25Amp

(30mA trip current)

3 Phase,25 Amp x 1

1 phase, 15 Amp x 1 for 230V

30 Amp x 2 for 115V

400V (3 Ph) x 1
230V (1 Ph) x 2

14 Pin Connector

6 Pin Connector

4-pole, 25Amp

(30mA trip current)

3 Phase,25 Amp x 1

1 phase, 15 Amp x 2

10A for Engine Battery Charging Circuit

10A for Wire Feeder Power

Advertising