3.2.3.2 SELECTING WORKPOINTS

Clicking on the workpoint display box in the waveform Editor window opens a Workpoint
pulldown menu. The pulldown menu displays the listing of workpoints defined for the active
waveform. Use the pulldown menu according to the following descriptions and guidelines:

Click on any one of the listed workpoints
to access the related waveform.

The related welding machine control
must be set to the selected parameter
value. If the welding machine setting is
not equal to the selected workpoint
value, changes to the wave shape will
be applied to the workpoint value
nearest the welding machine setting.

The welding machine Trim encoder must
be set to 1.00; the Arc control to “OFF”,
and the Mode control to “OFF”. Failure
to verify these welding machine
settings will defeat all wave shaping
efforts.