6. Adjust the Shorting Control Parameters (Optional)

The shorting control parameters can be adjusted to define how the welding machine will respond
when the arc shorts to the weld puddle.

To view the shorting control window, click on the button on the Waveform Editor screen.
Adjust the shorting control parameters to accommodate your welding application and per the
following parameter descriptions.

Appendix A

A-11

PULSE WAVE SHAPING PRINCIPLES

WAVE DESIGNER

AMPS

VOLTS

ARC

REESTABLISH

VOLTS

SHORT

DETECT

VOLTS

PINCH CURRENT

RISE PLATE

27850036

Shorting Control

Shorting Control

5

55.18

15

For Wire Feed Speed

Short Detect Volt

Pinch Current Rise Rate

Arc Restablish Volt

50

Short detect voltage: Adjust this parameter to set the detect voltage level that will start the
shorting response.

Pinch current rise rate (shorting response): Adjust this parameter to set the current rise rate that
will be used to clear a short.

Arc reestablish volts: Adjust this parameter to set the detect voltage level that will end the
shorting response.