Pulse wave shaping principles, Adjust the start control parameters (optional), A-10 appendix a – Lincoln Electric IM649 Wave Designer User Manual

Page 42

Advertising
background image

5. Adjust the Start Control Parameters (Optional)

The start control parameters can be adjusted to define how the welding machine will respond
when the arc is struck.

To view the start control window, click on the button on the Waveform Editor screen.
Adjust the start control parameters to accommodate your welding application and per the
following parameter descriptions.

A-10

Appendix A

PULSE WAVE SHAPING PRINCIPLES

WAVE DESIGNER

Start Control - Pulse

Start Control

For Wire Feed Speed

Stage 1 : Wire Run In

Stage 2 : Striking Pulse

Stage 3 : Arc Length Control

Stage 4 : Current Control

Start Volt

Start Time

Start Amps

Strike Peak Time

Strike Peak Amps

Open Circuit Volt

48.0

2.0

28.0

50

50

550.0

150

27850035

STRIKE

PEAK AMPS

STRIKE

PEAK TIME

START TIME

ARC

STRIKE

OPEN

CIRCUIT

VOLTS

AVERAGE

START

AMPS

@

START

VOLTS

Open circuit voltage: Sets the power source output voltage for the torch idle condition (the
welding machine is on, but not welding).

Strike peak amps: Adjust this parameter to set the peak level for the arc-strike current spike.

Strike peak time: Adjust this parameter to set the duration of peak current for the arc-strike
current spike.

Starting volts: Adjust this parameter to set the gun voltage to be maintained during the arc
starting routine.

Starting time: Adjust this parameter to set the duration of the arc starting routine.

Starting amps: Adjust this parameter to set the average current level during starting.