1 address settings, Address settings – LT Security PTZ217X12 Installation Manual User Manual

Page 17

Advertising
background image

Installation Manual of 4-inch Speed Dome

8

are used to set the baudrate. The eighth and ninth switches are used to set the parity and
Manchester Code protocol. The tenth switch is reserved. Please refer to the section 1.2.3 to 1.2.6
for detailed settings.

Notes:

 The default dome address is 0. The default baudrate is 2400, and the default status of the 120Ω

terminator is OFF.

 The speed dome is self-adaptive to the Pelco-P, Pelco-D and Private-Code. You don’t have to set

the RS-485 control protocol by the DIP switch.

 The network speed dome does not need to be set the address, baudrate, protocol, etc. by DIP

switch.

1

2

3

4

5

6

7

8

9

10

Figure 1-13 DIP Switch Settings

1.2.1 Address Settings

The switches from 1 to 5 are used for setting the address of speed dome. You can refer to Table 1-1
and 1-2 for details of setting the speed dome address to a specific number.

Table 1-1 Set the Dome Address

Switch Number

Dome Address

1

2

3

4

5

0

OFF OFF OFF OFF OFF

DIP Switch

Advertising