Installation Manual of 4-inch Speed Dome

10

1.2.2 Baudrate Settings

The number 6 and 7 DIP switches are used for setting the baudrate of the speed dome. The
baudrate can be 2400bps, 4800bps, 9600bps and 19200bps. The baudrate will be set as 2400bps by
default if it is out of this range. Refer to the following table:

Table 1-3 Set the Baudrate of the Dome

Switch Number

Baudrate

6

7

2400

OFF OFF

4800

ON

OFF

9600

OFF

ON

19200

ON

ON

1.2.3 Protocol Settings

The number 8 and 9 DIP switches are used for setting the parity and Manchester Code protocol of
the dome. Refer to the following table:

Table 1-4 Set the Protocol of the Dome

8

9

Bosch

Manchester

OFF

ON

AD Manchester

ON

ON

Protocol

Self-adaptive

Others

1.3 Alarm In/Out Connections

The analog speed dome can be connected with 2 alarm inputs (0~12VDC) and 1 alarm output. The
network speed dome can be connected with 1 alarm inputs (0~12VDC) and 1 alarm output.
Refer to the following diagrams for the alarm output connections:

JQC-3FG

Relay

12VDC

GND

OUT

L

N

~220V AC

Relay Output

Dome

(10 A 250VAC)

Diagram (left)

Diagram(right)

30mA

OUT(n)

OUT(n)

+

-

DC

DC Load

Relay Output

Dome

OUT(n)

OUT(n)

Figure 1-14 Alarm Out Connections