LumaSense Technologies M67 User Manual

Page 50

Advertising
background image

M67, M67S Manual

49

14.2 M67/67S "Infraducer" specifications

General Specifications
Accuracy:**

±0.50% of full scale or 1.0°C (1.8°F) whichever is greater.

Resolution:

±0.1% of full scale span (FSS)

Repeatability:

±0.2% of full scale span (FSS)

Emissivity:

Digital setting 0.10 to 0.99 with 0.01 step

Optical System:

M67S: Non-parralex refractive optics focusable

from rear panel.
Field of View:

M67S: Visual sighting 4°. Infrared measurement definition MTS

see FOV diagram for M67 and optical resolution for M67S.
Focussing Distance:

M67S: 3 different versions cover 2‖ to infinity

(adjustable for sharp focussing on target).
Eyepiece:

M67S: Dioper type

Input Voltage:

24VDC nominal

Input Voltage Range:

18-40VDC

Output Current Span:

4-20mA linear standard

Minimum Output Current 3.8mA

Maximum Output Current 32mA
Response Time:

50mS for codes H and Q spectral response, 100mS for

all others. Response time defined as time required for output to reach

95% of its final value.
Load Resistance Max:

400 ohms for 24VDC input voltage, 1200 ohms for

40VDC input voltage.
Electrical Connections:

1) M67 — Two terminal screws molded into high

strength, high temperature thermoplastic 2) M67S — Four terminals

compression type.
Operating Ambient Temperature:
Without Cooling Jacket:

0° to 60°C (32° to 140°F).

With Air Purge Assembly:

120°C (250°F) rated for water cooling.

With Cooling Jacket:

Up to 315°C (600°F).

Storage Ambient Temperature:

– 30° to 80°C (– 20° to 160°F)

Relative Humidity:

90% Non-condensing

Vibration:

M67 — 3 g’s any axis continuous

Shock:

M67 — 50 g’s

Housing Material:

Stainless steel

Dimensions:

1) M67 — 2.0‖ dia. x 7.8‖ long (50mm x 200mm)

2) M67S — 2.0‖ dia. x 8.0‖ long (50mm x 203mm)
Weight:

1.9 lbs. (0.90kg)

Mounting:

Support block with four 0.200‖ (5mm) dia. holes and ―U‖

clamp. For more secure mounting, use of protective jacket

is recommended.
Optional Features:

NIST Traceable Calibration Certificate: Minimum of five points on

instrument temperature scale. Additional points as required at extra

cost per point.
FM Approved Version:

See Basic Model selection chart.

Peak/Valley Picker:

See accessories (electrical).

** 1. Accuracy is stated for target emissivity of 1.0 at specified focussed distance

and target having sufficient diameter to eliminate background influence.

** 2. Accuracy is stated for input voltage of 24VDC and load resistance of 250 ohms.

** 3. For Infraducer with M spectral band accuracy is limited to 0.75% FS.