IN 6/78-L Operating Manual

Introduction · 9

2 Introduction

2.1 Appropriate use

The IMPAC IN 6/78-L is a stationary pyrometer created for non-contact temperature
measurement of thin glass surfaces with a temperature range between 400 and 1100 °C.

2.2 Scope of delivery

Instrument, PC measurement and evaluation software InfraWin, works certificate, and an

operation manual.

Note: A connection cable is not included with the instrument and has to be ordered
separately (see Chapter

8

, Reference numbers).

2.3 Technical Data

Temperature range:

400 ... 1100 °C

Sub range:

Adjustable to any range within the temperature range. Min. span is 51 °C

Spectral range:

7.8 µm (FWHM: 0.6 µm)

Optics:

Silicon

Power supply:

24 V DC (18 to 30 V DC) nominal, ripple must be less than 0.5 V

Power consumption:

Max. 50 mA

Analog output:

Adjustable, 0 to 20 mA or 4 … 20 mA (linear)

Load:

Max. 500 Ohm at 24 V (Max. 200 Ohm at 18 V)

Digital Interface:

RS485 (half-duplex)

RS485 Bus Address:

Set via digital interface

RS485 Baud Rate:

1200 Bd to 115.2 kBd

Resolution:

0.1 °C on interface;
< 0.1% of temperature range at the analog output

Isolation:

Power supply, analog output, and digital interface are electrically isolated
from each other

Parameters:

Adjustable via interface: InfraWin 4.14s or higher or InfraWin 5:
Emissivity ε, transmittance t, exposure time t

90

, 0/4 to 20 mA analog output

range, sub temperature range, automatic clearing of the max. value
storage, external clearing of the max. value storage, clear times of the max.
value storage, address, baud rate, internal temperature, °C / °F

Emissivity ε:

10.0 to 125.0% adjustable via interface in steps of 0.1%

Transmittance t:

10.0 to 100.0% adjustable via interface in steps of 0.1%

Exposure time t

90

:

0.08 s; adjustable to 0.5 s; 1 s; 2 s; 5 s; 10 s; 30 s

Maximum / minimum
value storage:

Built-in single or double storage. Clearing with clear time t

clear

(off; 0.1 s; 0.25 s;

0.5 s; 1 s; 5 s; 25 s), via interface or automatically with the next measuring
object

Measurement
Uncertainty:

(with

ε

=1, t

90

=1 s)

0.7% of reading or 3.5 °C, whatever is greater, in °C
(T

amb

= 44 °C)

(Note: the pyrometer must be operate at least 30 min before these values are valid)