Replacement parts, Removing the burner door assembly, Natural gas burner (ultra low nox) – American Water Heater 318935-003 User Manual

Page 24

Advertising
background image

24

Replacement Parts

IMPORTANT: The following maintenance procedures are
for the Flame Guard™ Safety System components and
should be performed by a qualified person.
Replacement parts may be ordered through your plumber
or the local distributor. Parts will be shipped at prevailing
prices and billed accordingly. When ordering replacement
parts, always have the following information ready:
1. model, serial, and product number
2. type of gas
3. item

number

4. parts

description

See pages 31-32 for a list of available repair parts.

Removing the Burner Door Assembly

1. Turn off the gas to the water heater at the manual

shut-off valve (Figure 3).

2. Before performing any maintenance, it is important to

turn off the gas supply to the
water heater at the manual
gas shut-off valve. This valve
is typically located beside
the water heater. Note the
position of the shut-off valve
in the open/on position, then
proceed to turn it off (Figure
3).

3. Remove the outer door.
4. Remove the two screws

(1/4” nut driver) securing
the burner door assembly
to the combustion chamber
(Figure 23).

5. Disconnect the pilot tube

(7/16” wrench), the igniter wire from the igniter lead
wire, and manifold tube (3/4” wrench) at the gas
control valve/thermostat. Disconnect the sensor wires
(lift white lever outward, then gently pull the plug
downward). Also, use needle nose pliers to disconnect
the red (+) and white (-) thermopile wires from the gas
control valve/thermostat. See Figures 22 & 23.

Figure 23
Burner Assembly
Removal

Burner Door Screws (2)

Manifold Component Block

Burner Door

Temperature
Sensor

Manifold Tube

Pilot Tube

Viewport

Thermopile
Wire
Connections

Piezo Igniter Button

Gas Control Valve/
Thermostat

Temperature Sensor
Wire Connection

Outer Door
Not Shown

VAC

Igniter

Wire

Red

Wire

(Left

Side)

Pilot

Tube

Manifold

Tube

Igniter

Button

Figure 22
Gas Control Valve/
Thermostat

Igniter

Lead

Wire

White

Wire

(Right

Side)

VAC

Sensor

Wires

6. Grasp the manifold tube and push down slightly to free

the manifold, pilot tube, and thermopile.

7. Carefully remove the burner door assembly from the

burner compartment.

NOTE: Be sure not to damage internal parts.

Figure24A

NaturalGas(LowNox)

Burner Door Assembly

Burner

Use brush on this surface.

Pilot Assembly

Figure24B

NaturalGas(LowNox)

Burner Door Assembly

50K Models

Burner

Use brush on this surface.

Pilot Assembly

Natural Gas Burner (Ultra Low Nox)

Check the burner to see if it is dirty or clogged. The burner
may be cleaned with soft paint brush (Figure 24). Do not
use a wire brush or any tool that may damage the burner
screen. Important: Do not use the burner if the burner screen
is damaged. NOTE: Damage may be rips or holes in the
burner screen. Discoloration is normal.