Post process settings – Spectra Precision Survey Pro 3.80 Recon GPS Reference Manual User Manual

Page 11

Advertising
background image

Job Menu

11

Post Process Settings

-RE 6HWWLQJV

3RVW 3URFHVV



The Post Process card is used to configure the post processing raw
data storage settings.

Recording Interval

: is where you set the period for

receiver internal raw data recording. Set it to

Off

to

disable post processing data collection in survey pro and
to turn off receiver recording on configuration.

RTK Autonomous Points:

is where you specify action to

take when accepting autonomous points during RTK
data collection.

Do not store

: this option will prohibit acceptance

of autonomous points in RTK data collection
routines.

Prompt for layer

: this option will prompt the

user whenever an autonomous point is accepted.
The layer specified will be the default layer to
store autonomous points, but the user can over

ride at the prompt.

Store on selected layer

: this option will automatically store

autonomous points accepted during RTK data collection
routines on the specified layer.

Layer

: displays the layer selected to store autonomous points.

6HOHFW /D\HU : opens up a layer prompt to allow you to select an

existing layer or create a new layer to store autonomous points.

Session Monitor

: is where you select to use monitoring of post

processing status for the session screen. To have Survey Pro display
warnings during post processing data collection, check

Warn me if

,

and specify threshold values for the number of

SV

,

HDOP

and

memory

.

Advertising