NOTE: Ratings based on 1-1/4" pipe with friction loss neglected. Us-

ing 3/4" garden hose adapter, performance will be reduced approxi-

mately 15%. This pump does not deliver enough pressure to operate

lawn sprinklers properly.

OPERATION

1. Set pump on hard surface in water before starting.
2. Use the included garden hose adapater for 3/4" discharge line or

disconnect the adapter to use a 1-1/4" discharge.

3. Plug power cord into properly grounded 115 volt AC power outlet.

(See recommended grounding methods on front page). Will oper-

ate continuously whether partly or fully submerged. Submersible

utility pumps are intended to pump clean or dirty water or water-

like liquids at temperatures up to 104˚ F.

4. When the pump senses that it is no longer pumping water, the

pump will shut off automatically. The pump will then turn on every

three minutes for 5 seconds and then off if it does not sense any

water.

5. If water is sensed after the pump begins running, the pump will

continue pumping until the pump senses that it is no longer

pumping water.

6. To prevent unnecessary wear, unplug the pump from the power

output when not in use.

7. The pump is supplied with a 3/4" garden hose adpater. For use

with plastic pipe, remove the adapter and install the desired 1-

1/4" NPT fitting. DO NOT OVERTIGHTEN THE HOSE OR PLAS-

TIC ADAPTER FITTING. Finger tight plus 1/2 turn is sufficient.

Do not set pump directly on sand, dirt or mud.

Sand or mud-choked pumps can be back-

flushed clean.

Do not handle or carry the pump by the power

cord. Use the handle.

Extended usage of the pump in a partially

submerged or non-submerged situation may

cause the pump to overheat due to lack of heat dissipation from the

water. If this occurs, the pump will shut itself off until the motor cools

to its normal temperature. Repeated overheating may cause dam-

age to the pump.

MAINTENANCE

1. The motor housing of the pump is completely sealed and requires

no service. Disassembly of the motor housing or alteration of the

power cord voids all warranty.

2. The motor is a continuous duty type with an automatic thermal

overload protector device.

3. The pump can run against a partially restricted discharge, but

is designed to move large volumes of water with minimal back

pressure.

4. If the pump becomes clogged, remove the screen and clean out

the area.

5. Debris in the intake should be routinely removed from the bottom

of the pump to prevent damage to the pump, which will void the

warranty.

6. If necessary, remove the eight (8) screws holding the volute base

to the motor housing and clean the volute.

REPAIR PARTS

Repair Parts Listing

Description

1/4 HP Model

Impeller

020328

Adapter

137728

Bushing

137727

Coupling

020331

Base

020329

Screen

139492

This product is warranted for one year from the date of purchase or two years from

the date of manufacture, whichever occurs first. Subject to the conditions hereinafter

set forth, the manufacturer will repair or replace to the original consumer, any portion

of the product which proves defective due to defective materials or workmanship. To

obtain warranty service, contact the dealer from whom the product was purchased.

The manufacturer retains the sole right and option to determine whether to repair or

replace defective equipment, parts or components. Damage due to conditions beyond

the control of the manufacturer is not covered by this warranty.

THIS WARRANTY WILL NOT APPLY: (a) To defects or malfunctions resulting from

failure to properly install, operate or maintain the unit in accordance with printed

instructions provided; (b) to failures resulting from abuse, accident or negligence or

use of inappropriate chemicals or additives in the water; (c) to normal maintenance

services and the parts used in connection with such service; (d) to units which are not

installed in accordance with normal applicable local codes, ordinances and good trade

practices; and (e) the unit is used for purposes other than for what it was designed and

manufactured.

RETURN OF WARRANTED COMPONENTS: Any item to be repaired or replaced

under this warranty must be returned to the manufacturer at Kendallville, Indiana or

such other place as the manufacturer may designate, freight prepaid.

LIMITED WARRANTY

THE WARRANTY PROVIDED HEREIN IS IN LIEU OF ALL OTHER EXPRESS

WARRANTIES, AND MAY NOT BE EXTENDED OR MODIFIED BY ANYONE. ANY

IMPLIED WARRANTIES SHALL BE LIMITED TO THE PERIOD OF THE LIMITED

WARRANTY AND THEREAFTER ALL SUCH IMPLIED WARRANTIES ARE

DISCLAIMED AND EXCLUDED. THE MANUFACTURER SHALL NOT, UNDER

ANY CIRCUMSTANCES, BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR

SPECIAL DAMAGES, SUCH AS, BUT NOT LIMITED TO DAMAGE TO, OR LOSS

OF, OTHER PROPERTY OR EQUIPMENT, LOSS OF PROFITS, INCONVENIENCE

, OR OTHER INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY TYPE OR

NATURE. THE LIABILITY OF THE MANUFACTURER SHALL NOT EXCEED THE

PRICE OF THE PRODUCT UPON WHICH SUCH LIABILITY IS BASED.

This warranty gives you specific legal rights, and you may have other rights which

vary from state to state. Some states do not allow limitations on duration of implied

warranties or exclusion of incidental or consequential damages, so the above limitations

may not apply to you.