Easy do’s & don't’s for installing a sump pump – Star Water Systems ECP SERIES User Manual
Page 2

2
EASY DO’S & DON'T’S FOR INSTALLING A SUMP PUMP
© All rights reserved.
FOR YOUR PROTECTION, ALWAYS DISCONNECT
PUMP FROM ITS POWER SOURCE BEFORE HANDLING. Single
phase pumps are supplied with a 3-prong grounded plug to help
protect you against the possibility of electrical shock. DO NOT UNDER ANY
CIRCUMSTANCES REMOVE THE GROUND PIN. The 3-prong plug must be
inserted into a mating 3-prong grounded receptacle. If the installation does
not have such a receptacle, it must be changed to the proper type, wired and
grounded in accordance with the National Electrical Code and all applicable
local codes and ordinances. Three phase pumps require motor starting devices
with motor overload protection. Pumps must be installed in accordance with the
National Electrical Code and all applicable local codes and ordinances. Pumps
are not to be installed in locations classified as hazardous in accordance with
National Electrical Code, ANSI/NFPA 70.
“Risk of electrical shock” Do not remove power
supply cord and strain relief or connect conduit directly to the pump.
Installation and servicing of electrical circuits and
hardware should be performed by a qualified licensed electrician.
Pump installation and servicing should be performed
by a qualified person.
CAUTION
Pump should be checked frequently for debris and/or build
up which may interfere with the float “on” or “off” position. Repair and service
should be performed by an Authorized Service Station only.
CAUTION
Dewatering and effluent sump pumps are not designed for
use in pits handling raw sewage.
CAUTION
Maximum operating temperature for cast iron pumps must not
exceed 130°F (54°C). Thermoplastic pumps must not exceed 110ºF (43ºC).
CAUTION
CSA certified pumps must be operated submerged with
“off - on” level controls.
CAUTION
Submersible pumps must be operated in an upright position.
Do not attempt to start pump when tilted or laying on its side.
CAUTION
Do not operate a pump in an application where the Total
Dynamic Head is less than the minimum Total Dynamic Head listed on the
Head/Capacity Curves.
1. DO read all installation material with the unit.
2. DO inspect unit for any visible damage caused by shipping. Contact
dealer if unit appears to be damaged.
3. DO remove all debris from the basin. Be sure that the pump will have a
hard, level surface beneath it. DO NOT install on sand, gravel or dirt.
4. DO be sure that the area is large enough to allow proper clearance for
the level control switch(es) to operate properly.
5. DO Always Disconnect Pump From Power Source Before Handling.
DO always connect to a separately protected and properly grounded
circuit.
DO NOT ever cut, splice, or damage power cord (Only splice in a watertight
junction box).
DO NOT carry or lift pump by its power cord.
DO NOT use an extension cord.
6. DO install a check valve and a union in the discharge line.
DO NOT use a discharge pipe smaller than the pump discharge.
7. DO NOT utilize this unit for pumping gasoline or other hazardous liquids.
8. DO test pump immediately after installation to be sure the system is
working properly.
9. DO review all applicable governing codes and verify that the installation
conforms to each of them.
10. DO consult manufacturer for clarifications or questions.
11. DO consider a two-pump system with an alarm where an installation may
become overloaded or primary pump failure would result in property damages.
12. DO consider a D.C. Backup System where a sump or dewatering pump
is necessary for the prevention of property damages from flooding due
to A.C. power disruptions, mechanical or electrical problems or system
overloading.
13. DO inspect and test system for proper operations at least every 3 months.