Serialselect options, Serial sele, Serial select options – Adaptec 58300 User Manual

Page 68

Advertising
background image

Appendix C: Using the ARC Utility

68

7

At the prompt, select Yes to exit, then press any key to restart the computer. Any changes
you made in SerialSelect take effect after the computer restarts.

SerialSelect Options

The following table lists the available and default settings for each SerialSelect option and the
description of each option. The default settings are appropriate for most systems and appear in
bold type in the table. Adaptec recommends that you do not change the settings.

SerialSelect Options

Available Settings

Description

Controller Configuration

Runtime BIOS

Enabled
Disabled
Disabled:Scan bus

Controls the state of the BIOS at POST time.
When Enabled, the

HostRAID

controller BIOS

allows the controller to act as a bootable
device. Disabling the BIOS allows another
suitable

HostRAID

controller to act as the boot

device.

BBS Support

Device
Controller

When BBS support is set to Device base, the
system’s BIOS will list each attached bootable
device to the

HostRAID

controller as an

individual entry. When BBS support is set to
Controller base, the system’s BIOS will only list
the

HostRAID

controller in the system boot

order. This is useful in a multi-

HostRAID

controller configuration.

RAID Support

Enabled
Disabled

When there are active arrays in the system, will
not allow you to Disable RAID support.

POST Banner Display

Enabled
Disabled

When Enabled, the Adaptec banner, version,
and copyright is displayed. When Disabled, the
Adaptec banner, version, and copyright is not
displayed.

CTRL-A Message

Enabled
Disabled

When set to Enabled, the SAS

HostRAID

controller BIOS displays the Press <Ctrl> <A> for
ARC Utility message on your screen during
system bootup. If this setting is disabled, you
can still invoke the ARC utility by pressing
Ctrl+A after the SAS card BIOS banner appears.

Physical Drives Display
during Post

Enabled
Disabled

When Enabled, attached physical devices are
displayed during system POST. Displaying the
devices adds a few seconds to the overall POST
time.

PHY Configuration

PHY Rate

Auto, 1.5, 3.0

The data transfer rate between the

HostRAID

controller and devices. The default setting is
Automatic, which allows the SAS card to adjust
the speed as needed.

SAS Address

0-F

Specifies the last digit of a 64-bit SAS address
of the

HostRAID

controller, device, and each

port using a globally unique worldwide name
(WWN) identifier.

Controller Properties

PCI Slot: Bus:
Device:Function

None

Displays the path of the storage devices in a
Host RAID controller.

Interrupt (IRQ) Channel

None

Displays interrupt

I/O Port Address

None

Displays I/O port address