Van Air Systems E102 Elements User Manual

F101 series, Installation instructions, Warnings

Advertising
background image

PRINTED IN THE USA

© 2000 VAN AIR SYSTEMS INC. 2950 MECHANIC STREET, LAKE CITY, PA 16423

PAGE 1

FILTER
MODEL
F101-500

F101-1000

F101-1500

F101-2000

F101-3500

F101-5000

BOTTOM

BLIND FLANGE WEIGHT

(LBS.)

28

47

69

69

102

177

To reduce energy consumption from excessive pressure drop and minimize chance of contaminant carryover, install new elements
before pressure drop reaches 10 psid (except grade RD). Install new RD elements when hydrocarbon vapors are first detected
downstream or every six months, whichever comes first.

FIGURE 1 LONG FLANGE BOLT (F101-500 thru 2000)

BEFORE INSTALLING NEW ELEMENT(S), READ INSTRUCTION MANUAL CAREFULLY. NOTE SERIES OF FILTER HOUSING
(F101, F102 OR FHP) AND CONSULT THE APPROPRIATE SECTION FOR SPECIFIC INSTRUCTIONS.

WARNINGS

F101 SERIES

Close inlet and outlet shut-off valves (and open by-pass valve
if provided); or lock out compressed air supply to filter housing.

1.

APRIL 2000

P/N: 432-00128

INSTALLATION INSTRUCTIONS

E101/102 SERIES FILTER ELEMENTS

(FOR F101, F102 AND FHP SERIES FILTER HOUSING - ALL GRADES)

TABLE 1 BOTTOM BLIND FLANGE WEIGHTS
(F101 Series)

NOTE

Filter models F101-500 thru F101-2000 are equipped

with a single long flange bolt to permit rotating of blind

flange for access to elements.

DO NOT LOOSEN FLANGE BOLTS BEFORE THE
VESSEL IS COMPLETELY DEPRESSURIZED.

WARNING

On units with manual drain valve, stand clear and turn manual
valve until fully open. Leave valve open until all pressure is out
of filter housing and bottom blind flange is removed. On units
with automatic drain valves (timed electric type) allow valve to
cycle until all pressure is out of filter housing.

Provide support under blind flange to prevent it from falling
when bolts are removed.

Remove bolts from flange and lower blind flange for access to
elements.

Remove hex fastener from tie rod and remove used element
from housing. Discard used element properly.

2.

ENDCAP COLOR

Black

Green

Red

Blue

Zinc Plate

Black

GRADE

AA
A
B
C

DESCRIPTION

Extra Coarse Coalescing
Coarse Coalescing
General Purpose Coalescing
High Efficiency Coalescing

ENDCAP COLOR

Black

Green

Red

Blue

GRADE

RAA
RA
RB
RC
HT
RD

DESCRIPTION

Extra Coarse Particulate
Coarse Particulate
General Purpose Particulate
High Efficiency Particulate
High Temperature Particulate
Vapor Adsorbing

®

WARNING

BLIND FLANGES ARE HEAVY AND COULD CAUSE IN-
JURY IF ALLOWED TO FALL. SEE (TABLE 1) FOR BLIND
FLANGE WEIGHTS.