4.1 Connecting the electrical supply

All MaxxAir models require regular 3 prongs, ground with 120 volt power supply. Plug electrical cord into receptacle. If

using an extension cord be sure it is rated for at least 20 amps for the distance your cord is running. To be safe – make sure

no other equipment is plugged into the same circuit. The MaxxAir should run smoothly on 20 amp, 120 volt, and 60 Hz

circuit.

4.2 Connecting the water supply

Connect standard water hose to female fitting on the right side of your MaxxAir (looking at the fan blade side). If your water

pressure is above 60 pounds per square inch (p.s.i). you must use a pressure regulator (which can be found at your local

hardware store). Note: Do not connect to water source exceeding 60 p.s.i. – this can cause damage to your MaxxAir.

5.0 Operating procedures

Back your MaxxAir unit up to a fresh air source such

as an open door or window so the unit can pull in

fresh air from the outside. Next, make sure you have

a natural exhaust at the opposite end of the room, bay

or building such as a window, door or bay door. This

will ensure maximum efficiency from your unit.

Finally make sure there are no obstructions between

your MaxxAir and the people / area you need to cool.

5.1 Filling the units reservoir with water

Once your water hose is connected – open the water

flow valve (located on the front of your unit) only

one and quarter (1 1/4) turns. This water flow valve

adjusts the amount of water to the unit.

Next, turn water on and fill the reservoir with water. Listen carefully. You can hear

water filling the reservoir. Check your water connection – make sure there is no dripping. Once the reservoir is filled with

water the float valve will automatically shut off the water source. When you no longer

hear the water running – you know that the float valve is fully operational

(the water turns off automatically) and you are now ready to turn on the water pump.

Warning! Do not run water pump without water in the reservoir.

5.2 Turn-on pump

To turn-on the water pump - flip the toggle switch for the water pump to on. Switch is

located on front side of unit. Warning! Do not run water pump without water in the

reservoir. The water pump will now begin pumping water to the top of the unit so that

gravity will allow the water to run down the backside of unit inside and on the cooling

pads. (If the water is dripping off of the pads on to the floor – turn your fan on low –

close the flow valve a little to slow the water flow. After the pads are wet – you can








NOTE: EXTENDED COOLING ZONE: 40’ TO 50’ FROM MAXXAIR UNIT.

AIR MOVEMENT INCLUDES WARM AIR MIXING WITH COOLED AIR.

Advertising