Ventamatic CX36BD2SPD User Manual

Page 8

Advertising
background image

-8-

—————————

VENTAMATIC, LTD.

LIMITED WARRANTY

Ventamatic, Ltd. extends this warranty to the original occupying owner of the home where this product is installed,
that this product will be free from defects of material or workmanship for the time period listed by model number
below:

CX242DDWT, CX302DDWT

Limited10-Year

CX24BD2SPD, CX30BD2SPD, CX36BD2SPD

Limited 10-Year

No subsequent purchaser of the home in which the product is installed will be entitled to the benefits of this
warranty. Ventamatic, Ltd. will replace the defective part or component only and return the new part to you freight
prepaid. Customer must bear all other expenses incurred, including labor required for field repair or replacement,
and cost of return shipping of the defective part or component to Ventamatic. Customer must also bear the cost of
replacement of any part or component and the shipping charges incurred for the replacement and return of any part
or component not covered by this warranty, including parts or components damaged by customer.
Ventamatic, Ltd. reserves the right to demand and receive written evidence of the date of purchase before
undertaking to perform its obligations under this warranty. YOU SHOULD, THEREFORE, RETAIN YOUR SALES
SLIP FOR THE DURATION OF THE WARRANTY, AND ATTACH IT TO ANY EVENTUAL CLAIM.
In order to obtain the replacement of a part or component, you must select one of the following methods:

A) Return to factory.

Return postage prepaid the

fan or part you

believe to be defective to the address

below:

Ventamatic, Ltd.

100 Washington Street

Mineral Wells, TX 76067

B) Return to place of purchase.

It is suggested that you first contact the dealer to ascertain if they will honor the warranty.

There is no informal dispute settling mechanism available in the event of a controversy involving this warranty.

Any and all implied warranties shall be limited to the duration of the express warranty set forth above. In some
states, limitations of the duration of implied warranty do not apply. Ventamatic, Ltd. shall not be liable for incidental
or consequential damages, whether direct or indirect based upon breach of warranty, breach of contract,
negligence or tort. If any suit or other action is brought against Ventamatic by customer, Ventamatic and customer
irrevocably waive the right to trial by jury.

Purchase and installation of this product constitutes acceptance of the

terms of this warranty by customer.

COMMON INSTALLATION ISSUES

Motor Stops After 10-20 Minutes

A tight belt tension can cause the unit to overheat.

Insufficient intake or exhaust Net Free Air. Open more doors and windows or increase the amount of ventilation

in the attic.

Check the bearing assembly for resistance on belt driven models to ensure there are no rough spots.

Unit is Noisy

If the unit is considered to be too noisy in general, install the additional frame between the fan and mounting

frame.
These are large fans and will make noise while under operation. Moving the fan further into the attic will reduce
the apparent noise. Make sure that you still have 36-in of clearance to the roof.

Check that all screws and bolts are tightened.

Ensure enough clearance above the unit, minimum of 36-in from fan blades to roof.

Verify Exhaust NFA. Inadequate NFA will result in the unit working harder and making more noise.

Not Enough Airflow

Verify NFA intake and exhaust requirements are being met. Lack of airflow can be the result of lack of fresh air

and lack of ventilation to expel the air. Try channeling the air by opening only doors and windows in a certain
area to funnel the wind flow.

*