Caution, Plate round bars & pipes – Walker Magnetics NEO-HV SERIES User Manual

Page 11

Advertising
background image

11

O.S. Walker Inc., NEO Permanent Lifting Magnets

: Each Walker magnet model is rated for a different weight limit, and the load
characteristics will affect the lifting capacity of the magnets. The lifting guidelines

for the various models are shown on the following pages.

The Lifting Guidelines charts show the effect of air gap, load thickness, load length, and load width on
lifting capacity. As the thickness of the load decreases, so does the rated lifting capacity of the mag-
net. The tables show the maximum weight or load size, which can be lifted for each thickness under
varying air gap conditions. DO NOT EXCEED EITHER THE MAXIMUM WEIGHT OR SIZE FOR
EACH THICKNESS.

Each value shown on the Lifting Guidelines charts is for AISI 1020 steel, and any increase in alloy
content will result in further reduction of the lifting capacity of the magnet.

THIS TABLE PROVIDES SOME REDUCTION FACTORS FOR

MATERIAL OTHER THAN AISI 1020 STEEL

Reduction Factors for Materials

Other than AISI 1020 Steel

Materials

REDUCTION FACTOR

Cast Steel

0.90

3% Silicon Steel

0.80

AISI 1095 Steel

0.70

416 Stainless Steel

0.50

Cast Iron (non-chilled)

0.45

Pure Nickel

0.10

For Other Materials Consult O.S. Walker

CAUTION

If you have any diffi culty lifting a load, DON’T LIFT IT!
Call Walker for advice at 1-800-962-4638

WARNING

GUIDELINES FOR THE REDUCTION OF THE

RATED LIFTING CAPACITY

Rated lift Capacity (For these materials) = Reduction Factor multiplied by Maximum Load
Value
(For 1020 Steel) from Lifting Guidelines (plate). See pages 12, 14 & 16.

Example: Lifting AISI 1095 STEEL, ½” thick, ROUGH machined fl at surfaces (use .020” air gap)
with a Model NEO-250 magnet.
Rated Lift Capacity = 0.70 multiplied by 160 = 112 pounds.

Rated lift Capacity (For these materials) = Reduction Factor multiplied by Maximum Load
Value
(For AISI 1020 Steel) from Lifting Guidelines (round bar & pipe). See pages 13, 15 & 17.

Example: Lifting CAST IRON, (non-chilled), 8” diameter solid round bar, CLEAN AND SMOOTH
GROUND surfaces (use 0” air gap) with a Model NEO-500 lifting magnet.
Rated Lift Capacity = 0.45 multiplied by 38” = 17.1”.

PLATE

ROUND
BARS &
PIPES

Advertising