Neo-1000, Lifting guidelines (round bars & pipes), Values are based upon aisi 1020 steel – Walker Magnetics NEO-HV SERIES User Manual

Page 19: Type of surface condition

Advertising
background image

19

O.S. Walker Inc., NEO Permanent Lifting Magnets

NEO-1000

LIFTING GUIDELINES

(ROUND BARS & PIPES)

Values shown are for maximum rated capacities when operating instructions and warnings are
followed.

VALUES ARE BASED UPON AISI 1020 STEEL

Higher alloy steels and other magnetic materials will require further reductions of these rated
capacities (See page 11 for the Guidelines for the reduction of the Rated Lifting Capacities.)

NEVER EXCEED EITHER THE MAXIMUM LENGTH OR WEIGHT SHOWN FOR EACH

ROUND BAR/PIPE DIAMETER, WALL THICKNESS & TYPE OF SURFACE CONDITION

Round

Bar/Pipe

Diameter

Inches

Pipe

Wall

Thickness

Inches

TYPE OF SURFACE CONDITION

CLEAN & SMOOTH

Similar to a Flat

(32 micro-inch RMS)

Ground Surface

.000” Max. Air Gap †

RUST OR SCALE

Similar to a Flat Hot

Rolled

Steel Surface

.010” Max. Air Gap †

(.254mm)

IRREGULAR OR ROUGH

Similar to a Flat Smooth

Cut File

.020” Max. Air Gap †

(.508mm)

Maximum Length

Inches

Maximum Load

Pounds

Maximum Length

Inches

Maximum Load

Pounds

Maximum Length

Inches

Maximum Load

Pounds

11”

(279mm)

MAX. DIAM.

3/8”

31”

117

27”

97

21”

77

1/2”

39”

182

35”

163

30”

141

1”

66”

587

58”

522

50”

449

SOLID BAR

40”

1100

34”

925

26”

720

8”

(203mm)

3/8”

46”

117

38”

97

30”

77

1/2”

54”

182

49”

163

42”

140

SOLID BAR

77”

1100

65”

925

50”

720

6”

(152mm)

3/8”

62”

117

51”

97

41”

77

1/2”

74”

182

67”

163

58”

140

SOLID BAR

137”

1100

115”

925

90”

720

4”

(101mm)

3/8”

96”

117

80”

97

63”

77

1/2”

116”

182

105”

163

90”

140

SOLID BAR

177”

629

177”

629

177”

629

3”

(76mm)

MIN. DIAM.

3/8”

133”

117

110”

97

87”

77

1/2”

114”

127

102”

114

89”

99

SOLID BAR

177”

354

177”

354

177”

354

NEVER LIFT ROUND BARS OR PIPES WITH:
A diameter LESS THAN 3 Inches or
A diameter GREATER THAN 11 Inches or
A wall thickness LESS THAN 3/8” (9.5 mm) or
A length greater than shown in the Lifting Guidelines above
(Absolute maximum length 177” (4500mm)

† Air Gap = nonmagnetic separation between magnet’s lifting surface and load.