Neo-500, Lifting guidelines (round bars & pipes), Values are based upon aisi 1020 steel – Walker Magnetics NEO-HV SERIES User Manual

Page 17: Type of surface condition

Advertising
background image

17

O.S. Walker Inc., NEO Permanent Lifting Magnets

NEO-500

LIFTING GUIDELINES

(ROUND BARS & PIPES)

Values shown are for maximum rated capacities when operating instructions and warnings are
followed.

VALUES ARE BASED UPON AISI 1020 STEEL

Higher alloy steels and other magnetic materials will require further reductions of these rated
capacities (See page 11 for the Guidelines for the reduction of the Rated Lifting Capacities.)

NEVER EXCEED EITHER THE MAXIMUM LENGTH OR WEIGHT SHOWN FOR EACH

ROUND BAR/PIPE DIAMETER, WALL THICKNESS & TYPE OF SURFACE CONDITION

Round

Bar/Pipe

Diameter

Inches

Pipe

Wall

Thickness

Inches

TYPE OF SURFACE CONDITION

CLEAN & SMOOTH

Similar to a Flat

(32 micro-inch RMS)

Ground Surface

.000” Max. Air Gap †

RUST OR SCALE

Similar to a Flat Hot

Rolled

Steel Surface

.010” Max. Air Gap †

(.254mm)

IRREGULAR OR ROUGH

Similar to a Flat Smooth

Cut File

.020” Max. Air Gap †

(.508mm)

Maximum Length

Inches

Maximum Load

Pounds

Maximum Length

Inches

Maximum Load

Pounds

Maximum Length

Inches

Maximum Load

Pounds

10”

(254mm)

MAX. DIAM.

1/4”

25”

55

19”

41

16”

35

1/2”

46”

197

37”

157

30”

130

1”

55”

440

42”

342

29”

235

SOLID BAR

24”

550

18”

420

12”

285

8”

(203mm)

1/4”

32”

55

24”

42

20”

35

1/2”

59”

197

47”

157

39”

130

SOLID BAR

38”

550

29”

420

20”

285

6”

(152mm)

1/4”

43”

55

32”

42

27”

35

1/2”

80”

197

64”

157

53”

130

SOLID BAR

68”

550

53”

420

35”

285

4”

(101mm)

1/4”

66”

55

50”

42

42”

35

1/2”

126”

197

100”

157

83”

130

SOLID BAR

154”

550

118”

420

80”

285

2 3/4”

(70mm)

MIN. DIAM.

1/4”

98”

55

75”

42

73”

35

1/2”

157”

157

157”

157

130”

130

SOLID BAR

157”

264

157”

264

157”

264

NEVER LIFT ROUND BARS OR PIPES WITH:
A diameter LESS THAN 2.75 Inches or
A diameter GREATER THAN 10 Inches or
A wall thickness LESS THAN 1/4” (6.4mm) or
A length greater than shown in the Lifting Guidelines above
(Absolute maximum length 157” (4000mm)

† Air Gap = nonmagnetic separation between magnet’s lifting surface and load.