Delmhorst Instrument Moisture Check User Manual

Page 13

Advertising
background image

Copyright

2005, Delmhorst Instrument Co.

Page 13 of 29

TO SET THE ALARM IN ENHANCED PIN MODE:

1. If you wish to set the alarm to beep after a pre-selected value is reached, use the

ò

key from the MC READ screen, highlight ALARM, and press the SELECT key to enter the
ALARM sub menu.

2. The default status of the alarm is “OFF.” Press the SELECT key to turn it on.

4. After the alarm is turned on, use the

п р keys to scroll up or down to a higher or

lower alarm value.

5. After you have selected the alarm value, use the

òkey to highlight DONE. Press

SELECT to get back to the MC READ screen


Default alarm settings in PIN mode are as follows for different materials:


All wood materials:

15%

Drywall:

1.0%

Concrete:

68 (on the 0-100 relative scale)



TO TAKE PIN READINGS IN ENHANCED MODE:

1. From the Enhanced Main Menu, use the

с т keys to highlight #1, PIN MODE.


2. Press the SELECT key to get into the ENHANCED READ screen. The current location

will stay the same while toggling between scan and pin modes.

This screen contains the following information: material, pin setting, temperature
correction, Job #, alarm setting, mode, and memory used.

3. Insert the pins into the material. The meter will start taking measurements in one of

the two following ways, depending on whether it is set for CONTINUOUS or
TRIGGERED mode. To choose between TRIGGERED or CONTINUOUS, use the
с т and п р keys to

highlight MODE, and then press the SELECT key to toggle

between TRIG and CONT.

Advertising