Unstable output/Sudden spiking
Unstable power supply, Inadequate grounding, Inadequate RFI protection.
1. Verify Power source.
2. Contact Detcon to optimize shielding and grounding.
3. Add RFI protection accessory.
4. Check area for after gas releases, such as cleaning chemical vapors.

Nuisance Alarms
1. Check condulet for accumulated water and abnormal corrosion.
2. If Nuisance alarms happening at night suspect condensation in condulet .
3. Add/Replace Detcon Condensation Prevention Packet P/N

960-202200-000

Transmitter not responding
1. Verify condulet has no accumulated water or abnormal corrosion.
2. Verify required DC power is applied to correct terminals.
3. Swap with a known-good transmitter to determine if transmitter is faulty.

Bad 4-20 mA output
1. Check that wiring is connected to correct terminal outputs.
2. Swap with a known-good transmitter to determine if transmitter is faulty.

3.13 Spare P

arts

600-500000-000

Sensor rain shield

600-610000-000

Sensor splash guard

943-000006-038

Threaded Calibration Adapter

399-800000-000

H2S sensor in stainless steel housing

924-015400-100

TP-424C Plug-in control circuit

500-005065-007

Connector board

960-202200-000

Condensation prevention packet (replace annually).

985-241100-321

In-Line Humidifying Tube

943-020000-000

Span Gas Kit: Includes cal adapter, In-Line Humidifying Tube, 200 ml/m span

gas regulator, and carrying case. Does not include span gas.

942-010112-010

Span gas bottle containing 58 liters 10ppm H2S in air (operating range dependent).

942-010112-020

Span gas bottle containing 58 liters 20ppm H2S in air (operating range dependent).

942-010112-025

Span gas bottle containing 58 liters 25ppm H2S in air (operating range dependent).

942-010112-050

Span gas bottle containing 58 liters 50ppm H2S in air (operating range dependent).

943-090005-502

200 ml/m regulator for span gas bottle

960-398800-000

H2S/MOS DRICAP w/desiccant (10 pack)

Detcon Model TP-424C Hydrogen Sulfide Sensor PG.14

H2S Sensor in SS Housing

Calibration Adapter

Rain Shield

Transmitter Assembly

Base Connector Board

Enclosure

Enclosure Cover

#6 x .125" Nylon Washer (X2)

6-32 X 3/8 Screw (X2)

#6 Star Washer (X2)
#6 Flat Washer (X2)

Condensation
Prevention Packet
(replace annually)

Advertising