Save/recall command – GW Instek GDS-1000 Series Programming Manual User Manual

Page 20

Advertising
background image

COMMAND

DETAILS

39

Note

Before using this command, select the
measurement channel. See the example below.

Example :measure:source

1

:measure:vmin?

Selects Channel 1, and
then measures the
minimum amplitude.

60B

:MEASure:VPP

Query

Description

Returns the peak-to-peak amplitude (difference
between maximum and minimum amplitude)
Same as: Measure key → F1~F5 → F3 (Vpp)

Syntax

< Long >

< Short >

:measure:vpp?

:meas:vpp?

Returns <NR3>

Note

Before using this command, select the
measurement channel. See the example below.

Example :measure:source

1

:measure:vpp?

Selects Channel 1, and
then measures the
peak-to-peak
amplitude.

61B

:MEASure:VRMS

Query

Description

Returns the root-mean-square voltage.
Same as: Measure key → F1~F5 → F3 (Vrms)

Syntax

< Long >

< Short >

:measure:vrms?

:meas:vrms?

Returns <NR3>

Note

Before using this command, select the
measurement channel. See the example below.

Example :measure:source

1

:measure:vrms?

Selects Channel 1, and
then measures the root
mean square voltage.

GDS-1000 Programming Manual

40

12B

Save/Recall Command

:MEMory<X>:RECall:SETup ........................................

244H

40

:MEMory<X>:RECall:WAVeform .................................

245H

40

:MEMory<X>:SAVe:SETup ..........................................

246H

41

:MEMory<X>:SAVe:WAVeform ...................................

247H

41

*RCL.............................................................................

248H

42

:REF<X>:DISPlay..........................................................

249H

42

:REF<X>:LOCate ..........................................................

250H

43

:REF<X>:SAVe..............................................................

251H

43

*SAV.............................................................................

252H

44

62B

:MEMory<X>:RECall:SETup

Set

Description

Recalls a panel setting from the internal memory.
Same as: Save/Recall key (recall) → F3

Syntax

< Long >

< Short >

:memory<x>:recall:setup

:mem<x>:rec:set

Parameter <X>

Internal memory

1 ~ 15

S1 ~ S15

Example :memory1:recall:setup

Recalls the settings from
the internal memory S1

63B

:MEMory<X>:RECall:WAVeform

Set

Description

Recalls a waveform from the internal memory and
saves it to a reference waveform.
Same as: Save/Recall key (recall) → F4

Syntax

< Long >

< Short >

:memory<x>:recall:waveform

<NR1>

:mem<x>:rec:wav
<NR1>

Parameter <X>

Internal memory

Advertising