GW Instek GDS-1000 Series Programming Manual User Manual

Page 22

Advertising
background image

COMMAND

DETAILS

43

Example :ref1:display

1

Turns on the reference
waveform A

68B

:REF<X>:LOCate

Set

Query

Description

Moves or returns the position of a reference
waveform.
Same as: Save/Recall key → F5 → Variable knob

Syntax

< Long >

< Short >

:ref<x>:locate

<NR1>

:ref<x>:locate?

:ref<x>:loc <NR1>
:ref<x>:loc?

Parameter

<X>

Reference

<NR1>

Position

1 A

–100 to +100

2 B

Note

Before using this command, turn on a reference
waveform. See the example below.

Example :ref1:display

1

:ref1:locate 0

Turns on the reference
waveform A and move
it to ±0 position

69B

:REF<X>:SAVe

Set

Description

Saves an input signal as a reference waveform.
Same as: Save/Recall key (save) → F2 → F2 → F3

Syntax

< Long >

< Short >

:ref<x>:save <NR1>

:ref<x>sav <NR1>

Parameter

<X>

Reference

<NR1>

Source

1 A

1

Channel 1

2 B

2

Channel 2

3

Math

GDS-1000 Programming Manual

44

Example :ref1:save

1

Saves the Channel 1
signal as the reference
waveform A

70B

*SAV

Set

Description

Saves the current panel settings into the internal
memory.
Same as: Save/Recall key

→ F1

Syntax *sav

Parameter

<NR1>

Internal memory

1 to 15

S1 to S15

Example *sav

1

Saves the current panel
settings into S1

Advertising