5. Press When repeatedly to
select the pulse condition.
Then use the Variable knob
to set the pulse width.
When <
20.0ns
VARIABLE
Condition
> , < , = , ≠
Width
20ns ~ 200us
6. Press Slope/Coupling to set
trigger slope and coupling.
Slope /
Coupling
7. Press Slope repeatedly to
select the trigger slope,
which also appears at the
bottom of the display.
Slope
Range
Rising edge, falling edge
8. Press Coupling repeatedly to
select the trigger coupling.
Coupling
AC
Range
DC, AC
9. Press Rejection to select the
frequency rejection mode.
Rejection
Off
Range
LF, HF, Off
10. Press Noise Rej to turn the
noise rejection on or off.
Noise Rej
Off
Range
On, Off
11. Press Previous menu to go
back to the previous menu.