Caution – HT instruments HT401 User Manual

Page 16

Advertising
background image

HT401

EN - 15

4.4.7. Diode and Continuity test

CAUTION

Before attempting any resistance measurement, cut off power supply from
the circuit to be measured and make sure that all capacitors are discharged,
if present.

Fig. 8: Diode and continuity test


1. Select the position

/

2. Press the MODE key to start testing diodes. The “

” symbol is shown at display

3. Insert the red cable into input lead

V

 and the black cable into input lead COM

4. Connect the red lead to the anode and the black lead to the cathode of the diode (see

Fig. 8). The instrument’s display shows the direct polarization voltage. This voltage is
typically 0.4 ~ 0.9V with good junctions.

5. Reverse connections and measure potential drop at the ends of the diode. An “O.L

result on the display indicates the correct operation of the junction.

6. Press the MODE key to select Continuity test. The “

” symbol is shown at display

7. Insert the red and black cables as described in “Resistance measurement” to carry out

the measurement. The buzzer is ON for resistance values < 30

8. For HOLD function please refer to § 4.2