Technical specifications – HT instruments HT401 User Manual

Page 20

Advertising
background image

HT401

EN - 19

6. TECHNICAL SPECIFICATIONS

6.1. TECHNICAL

CHARACTERISTICS

Accuracy is indicated as [% rdg + (dgt number) * resolution] at 23°C ± 5°C,< 80%HR

DC Voltage

Range Resolution Accuracy Input impedance

Protection against

overcharge

60.00mV 0.01mV

(0.08rdg+10dgt)

10M

 // < 100pF 1000VDC/ACrms

600.0mV 0.1mV

(0.08rdg+2dgt)

6.000V 0.001V
60.00V 0.01V
600.0V 0.1V

1000V 1V

AC TRMS Voltage

Range Resolution

Accuracy

(50Hz

1kHz)

Input impedance

Protection against

overcharge

60.00mV 0.01mV (1.2rdg+5dgt)

10M

 // < 100pF 1000VDC/ACrms

600.0mV 0.1mV

6.000V 0.001V

(0.8rdg+5dgt)

60.00V 0.01V
600.0V 0.1V

1000V 1V

For non-sinusoidal voltages, add the following errors depending on the crest factor (CF):
1.4 < CF < 2.0

 1%rdg to the accuracy

2.0 < CF < 2.5

 2.5%rdg to the accuracy

2.5 < CF < 3.0

 4.0%rdg to the accuracy

Max crest factor: 3.0 (0 ÷ 3000dgt); 2.0 (3000 ÷ 5000dgt); 1.6 (5000 ÷ 6000dgt)
PEAK HOLD feature: specified accuracy ±150dgt

AC + DC TRMS Voltage

Range Resolution

Accuracy

(50Hz

1kHz)

Input impedance

Protection against

overcharge

60.00mV 0.01mV (2.0rdg+10dgt)

10M

 // < 100pF 1000VDC/ACrms

600.0mV 0.1mV

6.000V 0.001V

(2.0rdg+5dgt)

60.00V 0.01V
600.0V 0.1V

1000V 1V

For non-sinusoidal signals, add the same errors as AC TRMS voltage
PEAK HOLD feature: specified accuracy ±150dgt

Auto-V (low impedance AC/DC voltage measurement)

Range Resolution Accuracy Input impedance

Protection against

overcharge

600.0VDC 0.1V

(0.8rdg+3dgt) about

3k

1000VDC/ACrms

1000VDC 1V

600.0VAC 0.1V

1000VAC 1V

For non-sinusoidal signals, add the same errors as AC TRMS voltage
PEAK HOLD feature: specified accuracy ±150dgt

Advertising