EN - 20

DC Current

Range Resolution Accuracy Measuring

time

Protection against

overcharge

60.00mA 0.01mA

(0.8rdg+3dgt)

3min (A)

10min (mA)

max 440mA (mA)

max 11A (A)

600.0mA 0.1mA

6.000A 0.001A
10.00A 0.01A

AC TRMS Current

Range Resolution

Accuracy

(50Hz

1kHz)

Measuring time

Protection against

overcharge

60.00mA 0.01mA

(1.2rdg+3dgt)

3min (A)

10min (mA)

max 440mA (mA)

max 11A (A)

600.0mA 0.1mA

6.000A 0.001A
10.00A 0.01A

For non-sinusoidal currents, add the same errors as AC TRMS voltage
PEAK HOLD feature: specified accuracy ±150dgt

AC + DC TRMS Current

Range Resolution

Accuracy

(50Hz

1kHz)

Measuring time

Protection against

overcharge

60.00mA 0.01mA

(2.0rdg+5dgt)

3min (A)

10min (mA)

max 440mA (mA)

max 11A (A)

600.0mA 0.1mA

6.000A 0.001A
10.00A 0.01A

For non-sinusoidal signals, add the same errors as AC TRMS voltage
PEAK HOLD feature: specified accuracy ±150dgt

Frequency

Range Resolution Accuracy

Minimum

frequency

Protection against

overcharge

100.00Hz 0.01Hz

(0.1rdg+2dgt)

1Hz 1000VDC/ACrms

1000.0Hz 0.1Hz

10.000kHz 0.001kHz

100.00KHz 0.01KHz

Sensitivity: > > 5.0Vpp (VAC 1Hz ~ 10kHz); > 10Vpp ( VAC 10kHz ~ 100kHz); > 2mApp (ACmA); > 0.2App (ACA)

Resistance

Range Resolution Accuracy

(*)

Maximum open

circuit voltage

Protection against

overcharge

600.0

 0.1

(0.8rdg+5dgt)

2.5V

(600

 and 6k)

1000VDC/ACrms

6.000k

 0.001k

(0.8rdg+2dgt)

60.00k

 0.01k

0.6V

(other ranges)

600.0k

 0.1k

6.000M

 0.001M

40.00M

 (*)

0.01M

(1.0rdg+5dgt)

Test current : approx. 0.1mA
(*) Specified for measurements 1 hour after Auto-V test. Add 10dgt for measurements before this interval
(**) Small instability < ± 50dgt for measurements >10 M

Diode test

Range Resolution Accuracy

Test

current

Open

circuit

voltage

Protection against

overcharge

2.000V 1mV

(1.5rdg+2dgt) < 0.4mA

<2.5V

1000VDC/ACrms

Advertising