Heading1 - 5.2 computing drawdown, 2 computing drawdown – In-Situ Virtual HERMIT Tutorial User Manual

Page 41

Advertising
background image

Drawdown Calculations

41

5.2

COMPUTING DRAWDOWN

The Virtual HERMIT software will also compute the drawdown while the
pump test is running. The drawdown is computed using the Level TROLL
that is in the pumping well (not the observation wells), which was selected
during the configuration of the HERMIT and Level TROLL instruments.

After the pump well TROLL is designated, the drawdown (how much the
water level has dropped from the start of data collection) is computed and
displayed on the screen for both the pump test (since start of test) and the
current step (since the last pump rate change).

The hydrologist can then see the drawdown values and the graphical
representation of what is happening in the pump well while performing the
test, allowing the hydrologist to determine when the next step should occur.

Level reminder

Set pump well to get drawdown

Set pump well to get drawdown

Drawdown and current step

Communication status

Advertising