ABC 040104

B-23/(B-24 Blank)

B.99

SYSTem:SET

COMMAND

SYST:SET

Syntax:

Short Form: SYST:SET {CM0 | CM1 | DC0 | DC1 | LF0 | LF1 | STR | RLX)
Long Form: SYSTem:SET {CM0 | CM1 | DC0 | DC1 | LF0 | LF1 | STR | RLX)

Description: Sending SYST:SET CM1 sets the unit to operate in compatible mode and have all GPIB functions

compatible with software version 1.2 and lower units. Sending SYST:SET CM0 sets the unit to be fully
SCPI 1997 compliant.

Sending SYST:SET DC1 causes Device Clear to be identical to *RST command. Sending SYST:SET
DC0 causes Device Clear to have no effect on output voltage, output current or output on/off state.

Sending SYST:SET LF1 causes the power supply to respond with line feed if read occurs with output
buffer empty. Sending LF0 causes the power not to send a line feed if read occurs with output buffer
empty (SCPI 1997 compliant).

Sending SYST:SET RLX allows the power supply to accept special debug and troubleshooting com-
mands (for KEPCO use only - e.g., after sending SYST:SET RLX the power supply will respond to the
$vda? command by returning the value of the internal D/A converter for voltage). Sending SYST:SET
STR disables the special debug and troubleshooting commands.

Related Commands:

SYST:PASS:CEN - the password must be enabled prior to saving the SYST:SET configuration using
the *SAV41 command.
*SAV41 - this command saves the configuration established by SYST:SET and OUTP commands and
restores it upon power up.

B.100

SYSTem:VERSion

QUERY

SYST:VERS?

Syntax:

Short Form: SYST:VERS?

Long Form: SYSTem:VERSion?

Return Value: <int_value>.<int_value> (YYYY.V)

Description: Identifies SCPI Version implemented. Returns SCPI Version number:

YYYY = year, V = Revision number for specified year. (See example, Figure B-8.)

FIGURE B-8. USING SYSTEM COMMANDS AND QUERIES

B.101

TRIGger:SOURce

COMMAND

TRIG:SOUR

Syntax:

Short Form: TRIG:SOUR {EXT | BUS}

Long Form: TRIGger:SOURce {EXT | BUS}

Description: Sending TRIG:SOUR activates the external trigger. When the external trigger (ground) is applied to J2

pin 3, output voltage and current are set to previously stored values for VOLT:TRIG and CURR:TRIG.
NOTE: If INIT:CONT 1 was sent prior to sending TRIG:SOUR EXT, continuous mode is disabled and
unit will wait for INIT:IMM. Related Commands: VOLT:TRIG and CURR:TRIG.

SYST:VERS?

Returns 2003.0.

SYST:KLOC ON

keypad locked, only remote control possible.

SYST:KLOC?

Returns 1 indicating keypad locked.

SYST:KLOC OFF

keypad unlocked, pressing LOCAL key allows Local mode
operation.

SYST:KLOC?

Returns 0 indicating keypad unlocked.