FIGURE B-3. USING LIST COMMANDS AND QUERIES (SHEET 2 OF 2)

LIST:GEN DSEQ

Changes the list to execute sequentially from locations 0 through 20).

LIST:COUN:SKIP?

Returns 4. Skip first 4 steps after the first time through count.

LIST:COUN:SKIP 0

Specifies no steps to be skipped after the first time through the count.

LIST:COUNT?

Returns 100.

LIST:COUNT 10

Determines that the list will be repeated 10 times when executed.

LIST:COUNT?

Returns 10.

VOLT:MODE LIST

Initiates execution of the list. The unit outputs a sawtooth waveform that
increases from -20V to +20V and repeats 10 times. There is an abrupt
change from +20V to -20V each time the list transitions from location 20 to
location 0.

VOLT?

Returns 20, (the last step in the list set the unit to 20V.

LIST:VOLT:POIN?

Returns 21 (the next location to be filled by LIST:VOLT).

LIST:VOLT 10,0,-10

Add 3 points to the list (location 21 through 23).

LIST:COUN?

Returns 10 indicating that the list will be repeated 10 times when executed.

LIST:DIR?

Returns UP (the default.)

LIST:DIR DOWN

Reverses the sequence order.

VOLT:MODE LIST

The list (24 steps) is executed. The output starts at -10V, goes to 0V, to 10V
to 20V then decreases to -20V in 2V steps and repeats 10 times. The saw-
tooth is similar to the previous sawtooth, except the waveform is inverted
and the abrupt change from -20 to +20 is executed in three steps of 10
volts.

LIST:GEN?

Returns DSEQ (default sequence))

LIST:GENERATION:SEQ

Changes sequence to user determined sequence.

VOLT:MODE:LIST

The original list of 4400 points will be executed (without the three new
steps.)

LIST:QUERy 0

Sets query pointer to zero.

LIST:DWEL:POIN?

Returns 1 indicating the next dwell time will be entered in location 1.

LIST:DWELL .01,.01,.01,.01,.01,.01,.01,.01,.01

Enters dwell time of 0.01 seconds in locations 1 through 9.

LIST:DWELL 1

Enters dwell time of 1 second in location 10.

VOLT:MODE LIST

the list is not executed, the unit returns error -221,Settings Error indicating
the lists are not balanced.

LIST:DWELL:POINTS?

Returns 11 to indicate the dwell list has 11 entries

LIST:VOLT:POINTS?

Returns 24 to indicate the voltage list has 24 entries.

LIST:DWELL .01,.01,.01,.01,.01,.01,.01,.01,.01,.01,.1,.1,.1

Dwell times are entered in locations 11 through 23.

DWELL:POINTS?

Returns 24 indicating there are now 24 step dwell times on the list.

LIST:QUER?

Returns 0 indicating list queries will start from location 0

LIST:QUER 18

Causes list queries to start at location 18

LIST:DWEL?

Returns .01,.01,.01,.1,.1,.1 (the dwell times for locations 18 through 23.

LIST:VOLT?

Returns 16,18,20,10,0,-10

LIST COUNT 0

List will repeat indefinitely.

VOLT:MODE LIST

The list is executed. Staircase wave now consists of 24 steps of .01 sec-
onds except for the 0V step (location 10) which outputs 0V for 1 second.
The end of the staircase has three steps of 0.1 second.

LIST:GEN?

Returns error -221,Settings Error because a LIST command cannot be
executed while the LIST is still being executed.

VOLT:MODE FIX

Stops execution of the list

VOLT?

VOLT?Returns -20 (the last step in the list set the unit to -20V.

VOLT: -4

Programs output to -4V

VOLT:MODE TRAN .05

Prepares for a voltage transient lasting 0.05 seconds.

VOLT:RANG 4

Sets unit to 1/4 scale (e.g., for BOB 20-20M, maximum voltage now 5V.

VOLT: 3

Output goes to +3V for 0.05 second, then returns to -4V.