Technical data – KROHNE OPTITEMP TR 100-TC 100 EN User Manual
Page 31

TECHNICAL DATA
7
31
OPTITEMP TR/TC 100
www.krohne.com
10/2009 - 4000630002 - MA OPTITEMP TR/TC 100 R02 en
The length of the connection wires is the same (40 mm / 1.58") for both variants (TR and TC 100).
Designation
TR/TC 100, Ø 3 mm / 0.118"
TR/TC 100, Ø 6 mm / 0.236"
[mm]
[inches]
[mm]
[inches]
a
Distance between fixing
screws
33
1.3
33
1.3
b
Washer disc thickness
1.5
0.06
1.5
0.06
c
Washer disc diameter
40
1.58
40
1.58
d
Sheath diameter
3
0.12
6
0.24
e
Sensitive sensor length
10...35
0.39...1.38
10...35
0.39...1.38
f
Measuring insert length
120
4.72
120
4.72
145
5.71
145
5.71
160
6.3
160
6.3
205
8.07
205
8.07
255
10.04
255
255
275
10.83
275
10.83
315
12.4
315
12.4
345
13.58
345
13.58
375
14.76
375
14.76
405
15.94
405
15.94
435
17.13
435
17.13
525
20.67
525
20.67
555
21.85
555
21.85
585
23.03
585
23.03
655
25.97
655
25.97
735
28.94
735
28.94
INFORMATION!
Different installation lengths are available on request.
.book Page 31 Thursday, October 8, 2009 10:26 AM