4.2
Connections
The input and output signals and the power supply must be connected in accordance with the
following illustrations. The in-head transmitter is easy to install with the KROHNE connection
head installation kit (see order information chapter 7.1). To avoid measuring errors, all cables
must be connected properly and the screws tightened correctly.
Figure 3: Installation diagram, TT 60 C/R
1
Pt100, Pt1000, Ni100, Ni1000, "SmartSense", 2-wire connection
2
Pt100, Pt1000, Ni100, Ni1000, "SmartSense", 3-wire connection
3
Pt100, Pt1000, Ni100, Ni1000, "SmartSense", 4-wire connection
4
Pt100, redundant sensor elements
5
Potentiometer, 2-wire connection
6
Potentiometer, 3-wire connection
1) SmartSense wire