Operation, 4 main overview – KROHNE PipePatro EN User Manual
Page 18

3
OPERATION
18
PIPEPATROL
www.krohne.com
02/2013 - 4002275001 - MA PipePatrol R01 en
3.3.4 Main Overview
An overview of the most important data for all pipelines is given in the "Main Overview". This
screen is also the start-up screen after a reboot of the station computer.
For each pipeline that is included in the leak detection system, the following information can be
seen:
• Actual volume/mass flow at inlet and outlet
• Actual temperature and pressure at inlet and outlet
• Description of the product at inlet and outlet (multi-product applications only)
• Graphical tracking of batches in the pipeline (for fluids applications only)
Figure 3-3: Main Overview screen
INFORMATION!
With a click on one of the available pipelines, the HMI will switch to the particular "Pipeline
Overview" screen (details on page 20
).