3.7.2 List of alarm messages

Message

Priority

Description

State E-RTTM Signature-

Test: Alarm

2

The E-RTTM module Signature-Test detects a leak.

State E-RTTM

Differential-Test: Alarm

2

The E-RTTM module Differential-Test detects a leak.

State Mass Balance

Differential-Test: Alarm

2

The Mass Balance module Differential-Test detects a leak.

State Shut-In Signature-

Test: Alarm

2

The Shut-In module Signature-Test detects a leak.

Shut-In Inlet: Alarm

Pressure Rising

2

The Shut-In module Signature-Test detects a leak and indicates that the

inlet transmitter shows a positive pressure wave.

Shut-In Inlet: Alarm

Pressure Drop

2

The Shut-In module Signature-Test detects a leak and indicates that the

inlet transmitter shows a negative pressure wave.

Shut-In Outlet: Alarm

Pressure Rising

2

The Shut-In module Signature-Test detects a leak and indicates that the

outlet transmitter shows a positive pressure wave.

Shut-In Outlet: Alarm

Pressure Drop

2

The Shut-In module Signature-Test detects a leak and indicates that the

outlet transmitter shows a negative pressure wave.

Leak Detection System:

Application Alarm

2

The system stopped working due to an internal error.

Alarm LDS-Watchdog

2

A failure of the leak detection system. The Leak Detection software is not

working correctly.