KROHNE CAPAFLUX IFM 5080 K Datasheet EN User Manual

Page 7

Advertising
background image

7

CAPAFLUX

CAPAFLUX

Local display

3-field LCD

Display function

actual flowrate, forward, reverse and sum totalizers (7-digit),
or 25-character bar graph with percentage indication and status messages

Units:

Actual flowrate

m

3

/h, liters, US gallons/min or user-defined unit, e.g. hecto-liters/day

Totalizer

m

3

, liters, US gallons or user-defined unit, e.g. hecto-liters or US million gallons

(adjustable count duration up to overflow)

Language of plain texts

English, German, French, others on request

Display:

Top field

8-character, 7-segment numeral and sign display,
and symbols for key acknowledgement

Middle field

10-character, 14-segment text display

Bottom field

4 markers to identify display in measuring mode

Power supply

1. AC Version

2. AC Version

AC/DC-Version

Standard

Option

Option

1. Rated voltage

230 / 240 V

200 V

24 V AC

24 V DC

Tolerance band

200 – 260 V

170 – 220 V

20 – 27 V AC

18 – 32 V DC

2. Rated voltage

115 / 120 V

100 V

Tolerance band

100 – 130 V

85 – 110 V

Frequency

48 – 63 Hz

48 – 63 Hz

Power consumption (incl. primary head)

approx. 10 VA

approx. 10 VA

approx. 8 W

When connected to functional extra-low voltage, 24 V, safety separation (PELV) is essential
(to VDE 0100 / VDE 0106 and IEC 364 / IEC 536 or equivalent national standard.)

Housing
Material

die-cast aluminium with polyurethane finish

Ambient temperature

– 25 to + 60°C (– 13 to + 140°F)

Protection category (IEC 529 / EN 60 529)

IP 67, equivalent to NEMA 6

Electrical connection

binar y outputs

and inputs

for

internal

use only

current output

PE 100 – 240 V AC

( PE protective conductor)

FE 24 V AC/DC

( FE functional ground)

B1

pulse output (P),
status output (S)
or control input (C)

B2

status output (S)
or control input (C)

Electrical connection in conformity with
VDE 0100 “Regulations gover-ning heavy-
current installations with mains voltages up
to 1000 V” or equivalent national standard.

If to be connected to a functional extra-low
voltage source (24 V), protective separation
in conformity with VDE 0100, Part 410, or
equivalent national standard, must be
ensured.

Current output (I)

Operating data of receiver instruments, outputs and inputs, see pages 6 and 7.

passive

active

passive

passive

Pulse output (P)

status output (S)

Control input (C)

(not with

Ex version)

P

electronic
or electro-

mechanical

totalizer

S

e.g.

signal

indicator

Advertising