5.3

Low-flow cutoff SMU

Fct. 1.03 L.F. CUTOFF
Press

→ key

Select

OFF

(fixed tripping points:

ON = 0.1 % / OFF = 0.2 %)

PERCENT

(variable tripping points:

ON = 1 – 19 % / OFF = 2 –20 %)

Select with

↑ and ↓ keys (only if PERCENT is selected).

1st number (cursor) flashes.

Setting the numerical value when “PERCENT” is selected

01 to 19

(cutoff “ON” value, left of hyphen)

02 to 20

(cutoff “OFF” value, right of hyphen)

Change flashing number (cursor) with

↑ and ↓ keys.

Use

← and → keys to shift cursor 1 place to left or right.

Flashing numbers (cursor) can also be directly set with the 10-key keyboard.
Press

↵ key to return to Fct. 1.03 L.F. CUTOFF.

Note: the cutoff “OFF” value must be greater than the cutoff “ON” value.

5.4

Display

Fct. 1.04 DISPLAY
Press

→ key

→ DISP.FLOW = select unit for display of flowrate, press

key.

NO DISP

no display

m

3

/hr

cubic meters per hour

Liter/Sec

liters per second

US Gal/min

US Gallons per minute

User-defined unit, factory setting = “Liter/hr” (liters per hour) or “US Mgal/day”, see sect. 5.14

PERCENT

Percentage display

BARGRAPH

numerical value and bar graph display in %

Select with

↑ and ↓ keys.

Press

↵ key to change to subfunction “DISP. TOTAL.”.

→ DISP. TOTAL. = select unit for totalizer display, press → key

NO DISP.

no display

OFF

internal totalizer switched off

+ TOTAL.

- TOTAL.

+/- TOTAL.

SUM (

Σ

Σ )

ALL (sequential)

Select with

↑ and ↓ keys.

Press

↵ key to change to display unit setting.

m

3

cubic meters

Liter

liters

US.Gal

US Gallons

user-defined unit, factory setting = “Liter” (liters) or “US Mgal/day”, see sect. 5.14.

Select with

↑ and ↓ keys.

Use

→ key to change to totalizer format setting.