KROHNE TIDALFLUX IFM 4110 PF EN User Manual

Page 71

Advertising
background image

7.30830.32.00

71

Local display

3-line LCD

Display function

current flow, forward, reverse and sum totalizers (7-digit) or 25-digit bar graph with
percentage display and status messages

Units:

actual flow

m

3

/hr, Liter/Sec, US gallons/min. or user-defined unit such as Liter/day or US MGal/day

totalizer

m

3

, Liter or US gallons or user-defined unit such as hectoliters or US MGal (adjustable

counting time up to overflow)

Language of clear texts

German, English, French

Display: 1st line

8-digit, 7-segment display for numbers/signs and symbols, for key acknowledgement

2nd line

10-character, 14 segment text display

3rd line

6 markers to identify current display in measuring mode

Field current supply
Type

bipolar, pulsed DC field, galvanically isolated from all output and input circuits

Terminals

7 and 8, each provided twice

Current/voltage

±

0.125 A (

±

5%) / max. 40 V

Clock frequency

1/36 to 1/2 of line frequency, adjustable acc. to calibration data of primary head
load: max. 220

Power supply

AC version

AC / DC version

standard

optional

voltage range
(without change-over)

100 – 230 V AC

24 V AC

24 V DC

Tolerance range

85 – 255 V AC

20.4 – 26.4 V AC

18 – 31.2 V DC

Frequency

48 – 63 Hz

48 – 63 Hz

-

Power input

12 W, typical

12 W, typical

12 W, typical

(max. 18 W)

(max. 18 W)

(max. 18 W)

When connected to a functional extra-low voltage, 24 V AC/DC, safety separation (PELV) must be
ensured (VDE 0100 / VDE 0106, IEC 536 or equivalent national regulations).

Field housing
Material

Diecast aluminium with polyurethane coating

Ambient temperature

in operation:

-25 to +60 °C / -13 to +140 °F

when stored:

-40 to +60 °C / -40 to +150 °F

Type of enclosure
(IEC 529 / EN 60529)

IP 65, equivalent to NEMA 4/4X

Advertising