4
ELECTRICAL CONNECTIONS
18
BATCHFLUX 5500 C
www.krohne.com
05/2014 - 4000827703 - HB BATCHFLUX 5500 R03 en
4.3.2 Cable connector M12 - 8 pin (with status output)
The 8 pin electric connection has a status output. This status output, is configurable to customer
specifications and offers either the flow direction (of the medium) or an error signal.
Options on status output 7; Off / Error / Flow direction
Mode
• Status output On / Off
• Flow direction
- Default value :Flow Direction
- Forward flow : status output; open
- Reversed flow ; status output ; closed
• Error software / application failure
Error signaling for following events: software failure or application failure (detection of empty
pipe only). No error ; status output open
1 + 24 VDC
2 Not Connected
3 To be connected for servicing only
4 Ground
5 Frequency output
6 Ground common I/O
7 Status output