Technical data, 1 measuring principle – KROHNE BATCHFLUX 5500 C EN User Manual
Page 21

TECHNICAL DATA
6
21
BATCHFLUX 5500 C
www.krohne.com
05/2014 - 4000827703 - HB BATCHFLUX 5500 R03 en
6.1 Measuring principle
An electrically conductive fluid flows inside an electrically insulated pipe through a magnetic
field. This magnetic field is generated by a current, flowing through a pair of field coils.
Inside of the fluid, a voltage U is generated:
U = v * k * B * D
U = v * k * B * D
U = v * k * B * D
U = v * k * B * D
in which:
v = mean flow velocity
k = factor correcting for geometry
B = magnetic field strength
D = inner diameter of flow meter
The signal voltage U is picked off by electrodes and is proportional to the mean flow velocity v
and thus the flow rate q. A signal converter is used to amplify the signal voltage, filter it and
convert it into signals for totalising, recording and output processing.
Figure 6-1: Measuring principle
1 Induced voltage (proportional to flow velocity)
2 Electrodes
3 Magnetic field
4 Field coils