6
TECHNICAL DATA
28
DK46I - DK47I
www.krohne.com
08/2008 • 4000360001 MA DK46I-47I-R01-en
6.4 Measuring ranges
Measuring span 10 : 1
Flow values 100%
Reference condition:
water 68°F (20°C)
air 68°F (20°C), 17.4 psi (1.2 bar abs.) in a standard state
Other flow rate measuring ranges can be provided upon request.
The conversion of other materials or operating data (pressure, temperature, density, viscosity) is
done with the help of the calculation procedure as detailed in Directive VDI /VDE 3513
Sphere Ø
mm
Water
Air
DK46 I
DK47 I
DK46 I
DK47 I
[GPH]
[l/h]
[GPH]
[l/h]
[SCFH]
[l/h]
[SCFH]
[l/h]
4
0.65
2.5
-
-
0.22
5
-
-
4
-
-
-
-
0.3
8
-
-
4
-
-
-
-
0.6
16
0.6
16
4
-
-
-
-
1.5
40
1.5
40
4
-
-
-
-
2.5
60
3.8
100
6
1.3
5
1.3
5
3.8
100
-
-
6
3
12
3
12
9
250
9
250
6
6.5
25
6.5
25
18
500
18
500
6
11
40
11
40
30
800
30
800
6
16
60
16
60
45
1200
-
-
6
25
100
25
100
-
-
-
-
8
30
120
-
-
-
-
-
-
8
42
160
-
-
-
-
-
-
MA_DK46I_47I_R01_en_PRT.book Page 28 Tuesday, August 5, 2008 7:03 AM