TECHNICAL DATA
6
31
DK46I - DK47I
www.krohne.com
08/2008 • 4000360001 MA DK46I-47I-R01-en
Control ranges
Control ranges
Control ranges
Control ranges
Inlet pressure regulator
Max flow rate
Water
Air
Min. inlet pressure Up1
[gal/h]
[l/h]
[ft
3
/h]
[l/h]
[psig]
[bar]
RE-1000
...10
...40
...35
...1000
7.3
0.5
RE-4000
...21
...80
...70
...2000
14.5
1
...26
...100
...106
…3000
21.8
1.5
...42
...160
...141
...4000
29
2
NRE-100
...0.66
...2.5
...3.5
...100
1.5
0.1
NRE-800
...8.8
...250
1.5
0.1
...28
...800
2.9
0.2
...6.6
...25
5.8
0.4
Outlet pressure regulator
Max flow rate
Water
Air
Min. pressure diff.
[gal/h]
[l/h]
[ft
3
/h]
[l/h]
[psig]
[bar]
RA-1000
...10
...40
...35
...1000
7.3
0.5
RA-4000
...26
...100
...70
…2000
14.5
1
...106
...3000
21.8
1.5
...42
...160
...141
...4000
29
2
NRA-800
...0.26
...1
...8.8
...250
1.5
0.1
...18
...500
2.9
0.2
...6.6
...25
...28
...800
5.8
0.4
MA_DK46I_47I_R01_en_PRT.book Page 31 Tuesday, August 5, 2008 7:03 AM