8.5.2 Procedure to remove a transducer

Step 1: Locate the suspect transducer

• Locate the position of the suspect transducer on the meter body.
• Switch off the electric power supply to the gas flowmeter.
• Remove the cover as necessary to gain access to the suspect transducer and the signal cable

that connect to the transducer.

In case of a warning, a problem or a failure, a technician using the diagnostic tool that is
available for the ultrasonic gas flowmeter, will be able to identify the number of the acoustic
path that most likely causes the problem.
The transducers are identified with codes as: 1U, 1D, 2U ... 6D. The number refers to the acoustic
path number. A "U" refers to the upstream transducer and a "D" refers to the downstream
transducer of an acoustic path.
For an ALTOSONIC V12 six transducers (belonging to three acoustic paths) are located on one
side (front) of the flowmeter. The codes and locations of these transducers are indicated in the
figure below.

Number in
picture

Description

1

Hand wheel at upper end of the main shaft

2

Adjusting disk to position the shaft

3

Locking device

4

Main shaft

5

Tube

6

Pressure relief valve

7

Clamping device

8

Handle to operate the ball valve

9

Ball valve

10

Intermediate flange

Only to be used for flowmeters with welded transducers

11

Wedge shape adapter

Only to be used for flowmeters machined out of one piece

12

Spring loaded hexagon at lower end of main shaft

13

Nut to fasten the transducer adapter

14

Transducer adapter

15

Nut to fasten the transducer in the transducer port

16

Transducer