Appendix, 1 namur ne 107 event group(s) – KROHNE UFC 400 Modbus EN User Manual
Page 27
Advertising

APPENDIX
8
27
UFC 400
www.krohne.com
05/2013 - 4002744801 - AD Modbus UFC 400 R01 en
8.1 NAMUR NE 107 Event Group(s)
Modbus Input Register
39004
39005
Byte 0
Byte 1
Byte 2
Byte 3
Byte
Bit
Status
signal
Event group
3
7
-
reserved
6
-
reserved
5
-
reserved
4
-
reserved
3
-
reserved
2
-
reserved
1
I
Electr: Operation Info
0
-
reserved
2
7
-
reserved
6
S
Electr: IO Connection
1
5
S
Proc: Empty Pipe
1
4
S
Proc: Signal Lost
1
3
S
Proc: Signal Unreliable
1
2
S
Config: Totaliser
1
1
-
reserved
0
I
Electr: Power Failure
1
1
7
S
Sensor
6
S
Electronics
5
S
Configuration
4
S
Process
3
M
Sensor
2
M
Electronics
1
M
Configuration
0
M
Process
0
7
F
Sensor
6
F
Electronics
5
F
Configuration
4
F
Process
3
C
Sensor
2
C
Electronics
1
C
Configuration
0
C
Process
1 Those event groups can be mapped to any status signals.
Advertising