Installation, 4 mounting position – KROHNE OPTIFLEX 1100C EN User Manual
Page 13

INSTALLATION
3
13
OPTIFLEX 1100 C
www.krohne.com
01/2012 - 4001721801 - HB OPTIFLEX 1100 R01 en
• Attach the counterweight.
• Attach the lock screws to the counterweight. Tighten with a 3 mm Allen wrench.
i
The device is prepared for installation on the tank.
If you decreased the probe length, you must enter the new value in the device configuration
menu (NOTE: the device must have the LCD display option or the HMI service tool). For more
data, refer to
Quick Setup
on page 44.
3.1.4 Mounting position
Attach the counterweight
Figure 3-4: How to assemble the single cable probe: part 2
1 Single cable probe
2 Counterweight
3 2 HC M6×5 lock screws
CAUTION!
Make sure the cable is fully engaged in the probe counterweight.
Figure 3-5: Cable probe: minimum distance from metallic walls and other metal objects
a ≥ 300 mm / 12¨