Electrical connections, 2 optional limit switches – KROHNE BM 26 BASIC_ADVANCED EN User Manual
Page 29
ELECTRICAL CONNECTIONS
4
29
BM 26 BASIC/ADVANCED
www.krohne.com
10/2012 - 4000347004 - HB BM26 Basic/Adv R04 en
4.2 Optional limit switches
• Remove the terminal compartment cover.
• Connect the device to the electrical circuit. Obey the national electrical codes.
For more electrical data, refer to
Technical data: optional limit switches
on page 56.
Figure 4-4: Terminal compartment
1 Terminal compartment cover
2 Bistable reed switch
3 Output terminal
1 2 3
WARNING!
If the switch is set to LOW limit
LOW limit
LOW limit
LOW limit, make sure that switch is open
open
open
open when the float is below the switch
position.
If the switch is set to HIGH limit
HIGH limit
HIGH limit
HIGH limit, make sure that switch is open
open
open
open when the float is above the switch
position.
Figure 4-5: Electrical schema
1 Non-NAMUR version