8
TECHNICAL DATA
64
BM 26 BASIC/ADVANCED
www.krohne.com
10/2012 - 4000347004 - HB BM26 Basic/Adv R04 en
Note:
• C-C = Face-to-centre length (process connections)
• ML = Measuring length
• L = Overall length
• a = Distance from the axis of the bottom connection to the bottom of the device;
b = top dead zone
Basic version: Top axial / Bottom lateral process connections
Figure 8-5: Top axial / Bottom lateral process connections
1 Optional drain with 3/8 NPT or 1¼ NPT connection (with plug - 1¼ NPT connection is for removal of the float from the
bottom of the device)
2 3/8 NPT threaded connection
3 Flange connection
4 Optional long stud (½¨ or ¾¨) connection
5 Optional male thread (½... ¾ NPT or G ½...¾) connection
6 Optional limit switch
7 Level indicator with optional scale
8 Optional support bracket - also refer to "Support bracket option: Dimensions and weight"