Installation, 5 theoretical data for nozzle position – KROHNE BM 702 A EN User Manual
Page 16
3
INSTALLATION
16
BM 702 A
www.krohne.com
09/2009 - 4000643301 - MA BM 702 A R01 en
3.5 Theoretical data for nozzle position
CAUTION!
Follow these recommendations to make sure that the device measures correctly.
Figure 3-2: Recommended nozzle position for liquids, pastes and slurries
1 Nozzles for DN150 or Wave-Stick antennas
2 Nozzles for DN200 antennas
3 Tank diameter
4 Minimum distance of nozzle from the tank wall depending on:
1 1/7 x tank height
2 1/10 x tank height
Maximum distance of nozzle from the tank wall depending on:
1 1/3 x tank diameter
2 1/3 x tank diameter
5 Tank height
INFORMATION!
If possible, do not put a nozzle on the tank centerline.
CAUTION!
Do not put the device near to the product inlet. If the product that enters the tank touches the 
antenna, the device will measure incorrectly. If the product fills the tank directly below the 
antenna, the device will also measure incorrectly.
.book Page 16 Thursday, September 3, 2009 2:53 PM