8.4 Antenna selection
The graph below shows which antenna to select for the application.
Graph of tank height / measuring range against dielectric constant ε
r
Figure 8-2: Selection of antenna
a = tank height / measuring range [ft / m]
b = ε
r
for storage tanks with smooth product surface
c = ε
r
for process tanks or foam
d = ε
r
for agitator tanks with vortex
1 Stilling well* (not for agitator tanks)
2 Stilling well* (not for agitator tanks) or antenna type 4
3 Stilling well* (not for agitator tanks); Wave-Stick or antenna type 3 and type 4
4 Stilling well* (not for agitator tanks); antenna type 2, type 3 and type 4 or Wave-Stick
5 Stilling well* (not for agitator tanks) or Wave-Stick
* Stilling well is equal to Wave-Guide antenna and bypass chamber